Wind direction | |
Measuring range | 0 ° ... 360 ° |
Resolution | 0.1 ° |
Accuracy | ±1 ° |
Starting value | < 0.5 m/s at 10 ° acc. to ASTM D 5096-96 < 0.2 m/s at 90 ° acc. to VDI3786 page 2 |
Distance constant | < 1.8 m acc. to ASTMD 5096-96 |
Damping ration | > 0.3 acc. to ASTMD 5096-96 |
Data output digital | |
Interface | RS485 |
Baudrate | 1200 ... 57600 Baud |
Protocol | ASCII |
Operating voltage | |
Electronic | 3.3 ... 42V DC |
Current consumption | 0.5 mA without data query 1.0 mA with data query |
Heating | without heating |
General | |
Ambient temp. | -50 ... +80 °C, all occurring situations of rel. humidity |
Electr. connection | 8 pol. plug connection |
Mounting | onto mast tube Ø 1 `` |
Material | aluminium anodised, stainless steel |
Protection | IP 55 |
Dimension | Ø 450 x 410 mm |
Weight | 0.7 kg |
Mounting | Ø 35 x 25 mm |