Wind direction | |
Measuring range | 0 ... 360 ° |
Resolution | 1 ° |
Accuracy | see models |
Starting value | < 0.5 m/s at 90 ° |
Damping ration | > 0.3 acc. to ASTMD 5096-96 |
Data output analog | |
Wind direction | see models |
Operating voltage | |
Potent. / Electronik | 0 ... 12 V DC, max 1.5 W |
Heating | 24 V AC/DC, 20 W |
General | |
Ambient temp. | -35 ... +80 °C |
Electr. connection | 8 pol. plug connection |
Mounting | onto mast tube Ø 1,5 `` |
Protection | IP 55 |
Dimension | Ø 850 x 415 mm |
Survival speed | 60 m/s |
Weight | 1.8 kg |
Mounting | Ø 50 x 50 mm |
Wind direction | |
Measuring range | 0 ... 360 ° |
Accuracy | ±2 ° |
Data output analog | |
Wind direction | 0 ... 2 kΩ |
Operating voltage | |
Potent. / Electronik | Current limiting to max. 1 mA |
Wind direction | |
Measuring range | 0 ... 358 ° |
Accuracy | ±3 ° |
Data output analog | |
Wind direction | 0 ... 400 Ω |