Wind speed | |
Measuring range | 0 ... 40 m/s |
Accuracy | ±1 m/s rms (< 10 m/s) ±5 % rms (> 10 m/s) |
Wind direction | |
Measuring range | 0 ... 360 ° |
Accuracy | ±10 ° |
Precipitation | |
Measuring range general | 1 / 0 ( yes / no ) |
Intensity measuring range | 0…15 mm/h |
Measuring range Quantity | 0…999,999 mm |
Measuring range hail | 1/0 (yes / no) |
Moisture | |
Measuring range rel. humidity | 0 … 100% |
Relative humidity accuracy | ±10% rel. F @ 20°C @ WS > 2 m/s |
Measuring range abs. humidity | 0 ... 400 g/m3 |
Radiation | |
Measuring range | 0 ... 1300 W/m² |
Accuracy | ±10 % of meas. range |
Temperature | |
Measuring range | -30 ... +60 °C |
Accuracy | ±1 K @ -5 ... 25 °C ( WS > 2 m/s ) |
Brightness | |
Measuring range | 0 ... 150 kLux |
Accuracy | ±3 % of meas. range |
Twilight | |
Measuring range | 0 ... 999 Lux |
Accuracy | ±10 Lux of meas. range |
Air pressure | |
Measuring range | 300 ... 1100 hPa |
Accuracy | ±0.5 hPa @ 20 °C |
Data output digital | |
Interface | RS485 ( half duplex ) |
Baudrate | 1200 ... 115200 Baud |
Protocol | ASCII; Modbus RTU |
Interface | |
Wireless | WIFI + MQTT, WIFI + LoRaWAN |
Operating voltage | |
Electronic | 18 ... 30VDC, 18 ... 28VAC |
Current consumption | 120mA @ 24 V (max. 1,5A AC, max 0,5A DC) |
General | |
Time synchronization | GPS |
Ambient temp. | -30 ... +60 °C |
Electr. connection | 7 pol. Stecker |
Mounting | on mast tube Ø 25mm` |
Dimension | Ø 130 x 132 mm |
Weight | 0.22 kg |
Data output digital | |
Protocol | ASCII |
Interface | |
Wireless | WIFI + LoRaWAN |
Data output digital | |
Protocol | Modbus RTU |
Interface | |
Wireless | WIFI + MQTT |
Data output digital | |
Protocol | Modbus RTU |
Interface | |
Wireless | WIFI + LoRaWAN |
Data output digital | |
Protocol | ASCII |
Interface | |
Wireless | WIFI + MQTT |