Wind speed | |
Measuring range | 0 ... 60 m/s |
Resolution | 0.1 m/s ( standard ) |
Accuracy | 0 ... 10 m/s ± 0.25 m/s (rms - mean over 360 °) 10 ... 30 m/s ± 2.5 % (rms - mean over 360 °) 30 ... 60 m/s ± 3.5 % (rms - mean over 360 °) |
Wind direction | |
Measuring range | 0 ... 360 ° |
Resolution | 1 ° 0.1 ° in special telegrams |
Accuracy | ±2 ° WS > 2 m/s |
Data output digital | |
Interface | RS485 / RS422 |
Baudrate | 1200 ... 921600 Baud |
Data values | div. meas. data, date, time, check sum, Precipitation type according to Synop etc. |
Output range | 1 per 10 msec up to 1 per 60sec |
Status signals | heating, Meas section error, Temperature of meas section |
Protocol | ASCII ( preselected ) |
Data output analog | |
Type | max. 8 x 0 ... 10 V |
Wind speed | 0 ... 10 V |
Stromausgang | max. 400 Ω |
Wind direction | 0 ... 10 V |
Voltage output | min. 2000 Ω |
Operating voltage | |
Electronic | 6 ... 40V DC or 10 ... 28 V AC / typ. 50mA @ 24V |
Heating | 24 V AC/DC, typ 1,4 A @ 24V |
General | |
Bus operation | up to 98 sensors |
Electr. connection | 19 pol. connector |
Mounting | on a mast tube 1,5`` |
Housing | Plastic LEXAN (Polycarbonat, UV-stabilised) |
Protection | IP 67 |
Data output digital | |
Protocol | ASCII Thies format |
Data output analog | |
Output parameters | wind speed, wind direction, etc. |
General | |
Dimension | Ø 150 x 175 mm |
Weight | 0.7 kg |
Data output digital | |
Protocol | MODBUS RTU ( preset ) |
Data output analog | |
Output parameters | wind speed, wind direction, etc. |
General | |
Dimension | Ø 150 x 175 mm |
Weight | 0.7 kg |
Precipitation | |
Measuring range general | 0.001 ... 10 mm/min |
Accuracy | typ. 95% |
Radiation | |
Measuring range | 0 ... 2000 W/m² |
Accuracy | ± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun position |
Temperature | |
Measuring range | -50 ... +80 °C |
Accuracy | ±0,3 K ( @ 25 °C ) |
Rain Temperature | |
Measuring range | 5 … 50 °C |
Accuracy | 0,5 °C |
Rel. Humidity | |
Measuring range | 0 ... 100 % rel. h. |
Accuracy | ± 1.8 % rel. h. ( 10 ... 90 % rel. H. ) |
Brightness | |
Measuring range | 0 ... 150 kLux |
Accuracy | 3 % of measuring value |
Twilight | |
Measuring range | 0 ... 250 Lux |
Accuracy | 3 % of measuring value |
Air pressure | |
Measuring range | 260 ... 1260 hPa |
Accuracy | ±0.25 hPa @ - 20 ... +80 °C @ 800 ... 1100 hPa ±0.50 hPa @ - 20 ... +80 °C @ 600 ... 800 hPa ±1.00 hPa @ - 50 ... -20 °C @ 600 ... 1100 hPa |
Data output digital | |
Protocol | MODBUS RTU ( preselected ) |
Data output analog | |
Output parameters | wind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc. |
General | |
Dimension | Ø 150 x 220 mm |
Weight | 0.9 kg |
Precipitation | |
Measuring range general | 0.001 ... 10 mm/min |
Accuracy | typ. 95% |
Radiation | |
Measuring range | 0 ... 2000 W/m² |
Accuracy | ± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun position |
Brightness | |
Measuring range | 0 ... 150 kLux |
Accuracy | 3 % of measuring value |
Twilight | |
Measuring range | 0 ... 250 Lux |
Accuracy | 3 % of measuring value |
Data output digital | |
Protocol | MODBUS RTU ( preselected ) |
Data output analog | |
Output parameters | Wind speed, wind direction, brightness, precipitation, etc. |
General | |
Dimension | Ø 150 x 220 mm |
Weight | 0.9 kg |
Precipitation | |
Measuring range general | 0.001 ... 10 mm/min |
Accuracy | typ. 95% |
Radiation | |
Measuring range | 0 ... 2000 W/m² |
Accuracy | ± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun position |
Brightness | |
Measuring range | 0 ... 150 kLux |
Accuracy | 3 % of measuring value |
Twilight | |
Measuring range | 0 ... 250 Lux |
Accuracy | 3 % of measuring value |
Data output digital | |
Protocol | ASCII Thies format |
Data output analog | |
Output parameters | Wind speed, wind direction, brightness, precipitation, etc. |
General | |
Dimension | Ø 150 x 220 mm |
Weight | 0.9 kg |