Radiation | |
Measuring range | 0 ... 1500 W/m² |
Accuracy | ±1 W/m² ± 2.0 % of MW Range 100 to 1,500 W/m²., perpendicular incidence, Spectrum AM1.5 |
Sensor type | Monocrystalline silicon; 50mm x 33mm |
Temperature | |
Measuring range | -40 ... +90 °C |
Accuracy | 1.0 K in the range -35 ... 80°C |
Interface | |
Output | RS 485 - Modbus RTU |
General | |
Power supply | 24VDC (10 ... 28 VDC) |
Current load | Typically 25mA at 24VDC |
Ambient temp. | -35 ... +80 °C 0 ... 100% rel. humidity, including condensation |
Cable | LiYCY 4 x 0,25 mm² - black, UV resistant |
Protection | IP 65 |
Dimension | Ø 80 x 82 mm |
Weight | approx. 350 ... 470g |
General | |
Measuring value | Solar irradiance incl. cell temperature sensor |
Electr. connection | 3m cable |
General | |
Measuring value | Solar irradiance incl. cell temperature sensor |
Electr. connection | Plug |
General | |
Measuring value | Solar irradiance incl. cell temperature and Module temperature sensor |
Electr. connection | 3m cable |
General | |
Measuring value | Solar irradiance incl. cell temperature and Module temperature sensor |
Electr. connection | Plug |